Spray Foam Attic Insulation: Open vs Closed Cell, Cost
Spray foam attic insulation comes in two types: open-cell, at roughly R-3.5 per inch, and closed-cell, at roughly R-6.6 per inch. Closed-cell costs more per inch but needs less thickness and also acts as a vapor retarder. Either can work in a Minnesota attic, but the choice depends on whether you insulate the attic floor or the underside of the roof deck, and on moisture, shingle and code details covered below.
Reviewed by the Three Rivers Contracting project team · MN Residential Building Contractor BC760638
Open-cell vs closed-cell spray foam
Both products are sprayed as a liquid that expands into foam and seals air leaks as it goes. They differ in density, R-value and moisture behavior.
| Open-cell | Closed-cell | |
|---|---|---|
| R-value per inch (approx.) | 3.5 | 6.5 to 6.6 |
| Typical density | About 0.5 lb/ft³ | About 2 lb/ft³ |
| Air barrier | Yes | Yes |
| Vapor retarder | No, vapor-permeable | Yes at about 2 to 2.5 in. or more (1 perm or less) |
| Installed cost per board foot (example) | Lower | $1.10 to $1.40 in one contractor’s market |
| Thickness for about R-49 (calculated) | About 14 in. | About 7.5 in. |
R-values and density come from Green Building Advisor and Journal of Light Construction. The thickness row is our own arithmetic from those R-values. The cost figure is one contractor’s price from a JLC article, and Green Building Advisor notes regional prices can differ by a factor of two or three, so treat any number as a rough guide and get several bids. Price is driven by foam type, thickness, attic size and complexity, access, and whether a hybrid of both foams is used. A hybrid costs more than either alone because it requires two products and often two crews.
Where the foam goes: attic floor or roof deck
This decision matters more than the foam type.
On the attic floor
Foam sprayed on the attic floor keeps the attic cold and vented, like a traditional attic. The roof deck can still dry out, and you can see the underside of the sheathing. This is the more conservative approach for most Twin Cities homes, though it is usually costlier than blown-in insulation for the same R-value.
On the underside of the roof deck (unvented attic)
Here the attic becomes part of the conditioned space. This is common for cathedral ceilings, ducts in the attic, or complex rooflines. It brings extra risk, and the code has specific conditions.
Roof-deck concerns: moisture and shingles
Green Building Advisor’s Martin Holladay warns that if a roof leaks, moisture can build up between the foam and the sheathing. Closed-cell foam also stops the sheathing from drying inward, so he says it should only be used if the sheathing is bone dry. A small leak that would show as a ceiling stain in a vented attic can hide behind foam for years.
GAF says its limited warranties are not voided when shingles go over an unvented deck, but damage caused by the unvented attic or lack of ventilation is excluded. Shingles over unvented attics also run hotter, which can speed aging. If you are replacing the roof, ask your contractor and the shingle manufacturer to confirm warranty terms in writing for your exact product. GAF also notes that spraying foam under the deck does not by itself make an attic unvented: existing vents must be removed or closed off.
Minnesota code and R-values
The City of Duluth’s handout on Minnesota residential code section R806.5 lists conditions for unvented attic assemblies. They include that the attic is entirely inside the thermal envelope, that there is no Class I vapor retarder on the ceiling side, and, in Climate Zone 7 where Duluth sits, that air-impermeable insulation must be a Class II vapor retarder or carry a Class III coating. Air-impermeable insulation goes in direct contact with the underside of the roof sheathing, and the foam must meet flame-spread and smoke ratings and, depending on attic use, an ignition or thermal barrier. The handout also lists combination options totaling R-49 per the Minnesota Residential Energy Code table. Because code editions change and local officials interpret details, confirm current requirements with your city’s building department before work starts. Ask whether a permit or inspection applies to your project.
For a conventional vented attic, a long-standing Minnesota target is about R-49 at the ceiling. See our guide to attic insulation R-values and rebates in Minnesota for the details and incentives.
Spray foam and ice dams
Ice dams form when heat escapes into the attic and melts roof snow from below. Foam can help because it air-seals while it insulates, and air leakage is often the biggest contributor. But GAF still recommends ventilation where ice forms along the eaves, and a vented attic helps control ice dams. If you go unvented, the foam must be continuous and carefully detailed at the eaves. Read why ice dams form and how to stop them and roof ventilation 101 before deciding.
Pros and cons at a glance
- Pros: excellent air sealing, high R-value per inch, works in tight rafter bays, can bring ducts into conditioned space.
- Cons: higher cost, hard to remove later, hides roof leaks, fire-barrier and code requirements, and shingle warranty questions on roof-deck applications.
Our insulation services page lists the options we install. If your main goal is a cold-weather fix, a good air-sealing job plus blown-in insulation often gets most of the benefit for less money.
Questions about your own roof or home? Call (651) 565-1349 or get a free estimate from Three Rivers Contracting.
Frequently asked questions
Is open-cell or closed-cell better for an attic?
Neither is better everywhere. Closed-cell gives about R-6.5 per inch and acts as a vapor retarder, so it fits thin roof-deck applications. Open-cell is about R-3.5 per inch, costs less per inch, and is vapor-permeable. Moisture risk, thickness available, budget and code requirements decide it.
How much does spray foam attic insulation cost?
Prices vary widely by region, foam type, thickness and attic complexity. One contractor-written article cited about $1.10 to $1.40 per board foot for closed-cell, and Green Building Advisor says regional prices can differ two to three times. Get at least three written bids that state thickness and R-value.
Will spray foam void my shingle warranty?
GAF states its limited warranties are not voided by an unvented deck, but damage caused by the unvented attic or poor ventilation is excluded. Warranty terms differ by manufacturer, so get confirmation in writing for your specific shingles before foaming the roof deck.
Does spray foam stop ice dams?
It helps by sealing air leaks and adding insulation, so less heat reaches the roof. It is not a guarantee. Air sealing is the first fix, and ventilation recommendations still apply, especially near the eaves. A professional should evaluate the whole attic.
Do I need a permit to spray foam my attic?
Permit rules vary by city, and unvented attic assemblies have specific code conditions. Call your local building department or ask your contractor to confirm before work begins.