Faced vs Unfaced Insulation: Where Each Belongs in MN
Faced insulation has a paper or foil backing that works as a vapor retarder; unfaced does not. In Minnesota, kraft-faced fiberglass batts belong in exterior frame walls with the facing toward the heated side, while fiberglass batts for attic insulation are normally unfaced when you are adding to existing insulation. The most common mistake is stacking a second layer of faced batts, which can trap moisture between two retarders.
Reviewed by the Three Rivers Contracting project team · MN Residential Building Contractor BC760638
What the facing does
The facing is usually kraft paper, sometimes foil. The Insulation Institute lists vapor retarder classes: Class I at 0.1 perms or less (poly sheeting, foil), Class II above 0.1 and up to 1.0 perm, and Class III above 1.0 and up to 10 perms (latex paint). Kraft facing is about 1.0 perm, so it falls in Class II. The paper also gives you a stapling flange, though it is not an air barrier on its own. Kraft-faced insulation has no fire rating and should not be left exposed, according to Knauf, while unfaced insulation is Class A fire-rated.
Where each type belongs in Minnesota
| Location | Typical choice | Notes |
|---|---|---|
| Exterior frame walls | Faced (Class II) or poly (Class I) | Facing toward the heated interior; Minnesota rule requires Class I or II |
| Attic floor, first layer | Unfaced or faced, per your inspector | If faced, facing down toward the ceiling |
| Attic floor, added layer | Unfaced | Lay across the joists; never a second faced layer |
| Interior partition walls | Unfaced | Sound control; no vapor concern |
| Floors over cold spaces | Per design and inspector | Retarder goes on the warm side |
| Crawl space | Unfaced typical per Knauf | Moisture control depends on the whole crawl space design |
Minnesota amends the residential code: Rule 1309.0702 says a Class I or II vapor retarder is required on the interior side of frame walls in Climate Zones 6 and 7, and Class II is permitted only when specified on the construction documents. The Insulation Institute describes the same Zone 5 to 8 requirement in the model code. Kraft-faced batts satisfy this when installed correctly. For the attic floor, check with your building department, since this rule addresses walls.
Fiberglass batts for attic insulation
An attic floor in Minnesota needs a lot of insulation, and the long-standing target is R-49 per the Minnesota energy code table cited in unvented-attic guidance. See attic insulation R-values and rebates in Minnesota for numbers and incentives. For attics, here is how it usually plays out:
- Adding to an existing layer: use unfaced batts or blown-in insulation on top. Knauf says unfaced can go over existing insulation whether it is faced or unfaced.
- Building a new attic floor: a retarder at the ceiling plane is typical, so faced batts can work with the facing down, but the air barrier matters more than the paper.
- Air seal first. Light fixtures, top plates, chases and ducts leak far more moisture than diffusion through paper.
Green Building Advisor makes the same point: air leakage, not vapor diffusion, causes most moisture problems, so sealing matters more than which side the paper faces.
Common stacking mistakes
Faced over faced
Knauf warns it is not good practice to include two vapor retarders in an insulation system because trapped moisture may be unable to dry. A second kraft-faced layer on top of an old faced layer is the classic error. If you must add, use unfaced.
Facing the wrong way
Kraft facing usually goes toward the warm side of the assembly in winter. In a Minnesota wall, that means the paper faces the room. Facing toward the cold side can slow drying where you want it and speed condensation where you do not.
Compressed or gapped batts
Squeezing R-19 into a shallow space lowers its R-value, and gaps let warm air reach cold surfaces. Cut batts to fit around wiring and boxes.
Covering with poly and paper
Wall poly plus a faced batt, or foam board plus interior poly, can double up. Ask your contractor to review the whole wall assembly before closing it. Our guide to house wrap and weather barriers covers the outside side of the wall.
Quick decision guide
- Is it an exterior frame wall? Use a Class I or II retarder on the room side, such as kraft-faced batts, and follow the construction documents.
- Is it adding to an existing attic layer? Use unfaced batts or blown-in insulation, and air seal first.
- Is it a partition wall? Use unfaced batts, often for sound control.
- Are you unsure? Ask your building department or a licensed insulation contractor before you buy a pallet of batts. Returning and redoing a wall costs far more than a phone call.
How to tell if your home is under-insulated
Look for ice dams, uneven snow melt on the roof, cold ceilings or high heating bills. Our post on signs your home is under-insulated lists more. For help choosing materials and installing safely, see our insulation services.
Questions about your own roof or home? Call (651) 565-1349 or get a free estimate from Three Rivers Contracting.
Frequently asked questions
What is the difference between faced and unfaced insulation?
Faced insulation has a paper or foil backing that acts as a vapor retarder; unfaced has none. Kraft facing is about 1.0 perm, which is Class II. Unfaced is Class A fire-rated and can be left exposed, while kraft-faced should not be.
Which side does the facing go on in Minnesota?
In winter, kraft facing usually goes toward the warm side of the assembly. In a Minnesota exterior wall, the paper faces the heated interior. Minnesota rule 1309.0702 requires a Class I or II vapor retarder on the interior side of frame walls in Climate Zones 6 and 7.
Should I use faced or unfaced batts in the attic?
When adding insulation over an existing layer, use unfaced. Knauf says unfaced can be placed over faced or unfaced insulation. Avoid a second kraft-faced layer. For a new attic floor, ask your building department what retarder it expects.
Can I put faced insulation over faced insulation?
Avoid it. Knauf says it is not good practice to incorporate two vapor retarders, since trapped moisture may be unable to dry. Add unfaced batts or blown-in insulation across the joists instead, after air sealing.
Is kraft-faced insulation a fire hazard?
Kraft facing has no fire rating, according to Knauf, and should not be left exposed. Keep it covered by drywall or a code-approved covering. Unfaced fiberglass is Class A fire-rated and can be left exposed or used in fire-rated assemblies.